23. The comparison is carried out according to the following formula:
If RSSIcurr + RSSI Hysteresis ¿ RSSIRefCh - ERP DeltaR-C + BiasAdj-Curr
then stay in current cell, otherwise the current cell is not the ”best”.
The use of the RSSI Hysteresis value is discussed in a later section.